YYQW thermal oil boiler use the gas or heavy oil as fuel and the burner from both BALTUR and RIELLO brand are available.
Boiler Characteristics
With oil(gas) fuel and heat conducting oil as the medium,the hot oil cycling pumps forces the medium to recycle in liquid form to transfer heat to the heat equipment and send it back to the heat conduction furnace for reheating. The heater can get high working temperature under low pressure and the medium to conduct precision work.It features high heat utilization rate,whole module installation,simple operation and maintenance,thus its a type of ideal equipment that reliable,efficient and energy-saving. The high temperature flame generated by ignition of the oil(gas)by the burner forms the heating surface after entering the internal coil pipe. Rotating by 180 degree after passing the rear of the internal pipe,it forms convection heating surface in the inter-layer area of the internal and external pipes.Passing through the upper part,it enters the second inter-layer section of the two pipes,passes the rear part of the second inter-layer section and is discharged into the air through chimney.
Characteristics of thermal oil boiler
1. The heater can get low pressure and high temperature heat medium and features simple adjustment and even heating,enabling it to satisfy precise temperature demand.
2. Heating by liquid recycling;no heat loss due to condensation discharge;high heating rate of heat-supply system.
3. There are compensation measures in the system for heat-receiving and heat discharging of working media as well as volume changes due to temperature changes.
4. There are technical measures to strictly control volumes air,water and other low volatile in the working media before heat recycling.
Introduction of the thermal oil boiler control system
These series of thermal oil boiler are controlled by programmed controller,realizing all functions required by normal burning.It automatically realizes protective warning of accidents or other abnormal conditions. Together with the liquid level controller,pressure controller and temperature controller,the system realizes indications of pressure and temperature at the inlet and outlet,ensuring that the temperature and pressure fluctuate within the allowable ranges.
Model Number
|
YYQW-120 |
YYQW-240 |
YYQW-350 |
YYQW-500 |
YYQW-1000 |
YYQW-1200 |
YYQW-1800 |
YYQW-2100 |
WNS-3000 |
WNS-3500 |
WNS-4700 |
WNS-6000 |
WNS-7000 |
WNS
-10000 |
||
Rated thermal power |
kw |
120 |
240 |
350 |
500 |
1000 |
1200 |
1800 |
2100 |
3000 |
3500 |
4700 |
6000 |
7000 |
10000 |
|
Design pressure |
Mpa |
1.0 |
||||||||||||||
Medium temperature at outlet |
℃ |
≤350 |
||||||||||||||
Heating area |
㎡ |
9.8 |
14.8 |
21.3 |
24 |
50 |
64.6 |
87 |
94.5 |
163 |
205.2 |
254.3 |
325 |
410 |
520 |
|
Applicable fuel |
|
Light oil,Heavy oil,Gas |
||||||||||||||
Fuel consumption |
Light oil |
Kg/h |
12 |
25 |
37 |
52 |
100 |
120 |
180 |
210 |
300 |
350 |
470 |
580 |
680 |
970 |
Natural gas |
m³/h |
15 |
30 |
44 |
63 |
120 |
145 |
220 |
260 |
365 |
425 |
570 |
700 |
810 |
1160 |
|
Gas pressure |
Natural gas |
mbar |
30-100 |
50-150 |
50-200 |
100-300 |
||||||||||
Total power |
Light oil |
Kw |
4 |
8 |
10 |
10 |
26 |
26 |
46 |
46 |
66 |
78 |
98 |
115 |
115 |
132 |
Gas |
Kw |
4 |
8 |
10 |
10 |
25 |
26 |
46 |
46 |
64 |
72 |
95 |
110 |
110 |
128 |
|
Oil volume |
M³ |
0.1 |
0.15 |
0.25 |
0.3 |
0.8 |
0.85 |
1.2 |
1.7 |
3.5 |
3.8 |
4.2 |
6.2 |
7.0 |
10.5 |
|
Max.Transportation W.T. |
T |
1.5 |
2.0 |
2.6 |
3.0 |
5.0 |
5.8 |
7.8 |
8.8 |
15.5 |
17.8 |
21.5 |
25 |
27.5 |
32 |
|
External Dimension |
L |
mm |
1600 |
1930 |
2100 |
2200 |
3300 |
3830 |
4600 |
5020 |
5983 |
6555 |
7285 |
7800 |
8200 |
10000 |
W |
mm |
1020 |
1230 |
1390 |
1390 |
1670 |
1170 |
2000 |
2050 |
2420 |
2470 |
2570 |
3050 |
3050 |
3500 |
|
H |
mm |
1520 |
1868 |
2055 |
2055 |
2486 |
2587 |
3045 |
3080 |
3404 |
3643 |
3760 |
3800 |
3800 |
4000 |
Cooker is used in oil pressing plant to improve the oil yield and oil&meal quality by the function of moisture and steam.
New designed skid-mounted steam boiler using HFO/LPG/LNG as fuel,easy installation,cost saving and time saving etc.
DZL steam boiler use the coal,wood or biomass peller as fuel,easy operation.
Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.